Poddar Court, Gate # 4, 2nd Floor, 18, Rabindra Sarani, Kolkata - 700 001

Profibus Cables

/3079A

Multi-Conductor - DataBus® ISA/SP-50 PROFIBUS Cable

General Description :
22 AWG solid bare copper conductors, FRFPE insulation, Beldfoil® (100% coverage) plus a tinned copper braid shield (65% coverage), sunlight resistant PVC jacket.

Physical Characteristics (Overall)
Conductor : AWG :

 

# Pairs AWG Stranding Conductor Material Dia. (in.)
1 22 Solid BC - Bare Copper .026

Total Number of Conductors: 2

Insulation
Insulation Material:

  • Insulation Material : FRFPE - Flame Retardant Foam Polyethylene

Outer Shield
Outer Shield Material:


Layer # Outer Shield Trade Name Type Outer Shield Material Coverage (%)
1 Beldfoil® Tape Aluminum Foil-Polyester Tape 100
2 Braid TC - Tinned Copper 65

Outer Jacket
Outer Jacket Material:

 

Outer Jacket Material
PVC - Polyvinyl Chloride

Overall Cable
Overall Nominal Diameter : 0.315 in.

Pair
Pair Color Code Chart:
1. Red & Green

Pair Lay Length & Direction:
Lay Length (in.) : 2.750

Mechanical Characteristics (Overall)

  • Operating Temperature Range: -30°C To +75°C
  • UL Temperature Rating: 60°C
  • Bulk Cable Weight: 52 lbs/1000 ft.
  • Max. Recommended Pulling Tension: 50 lbs.
  • Min. Bend Radius/Minor Axis: 3.200 in.

Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs

  • NEC/(UL) Specification: CMG, PLTC
  • CEC/C(UL) Specification: CMG
  • AWM Specification: UL Style 20201 (600 V 75°C)
  • EU Directive 2011/65/EU (ROHS II): Yes
  • EU CE Mark: Yes
  • EU Directive 2000/53/EC (ELV): Yes
  • EU Directive 2002/95/EC (RoHS): Yes
  • EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
  • EU Directive 2002/96/EC (WEEE): Yes
  • EU Directive 2003/11/EC (BFR): Yes
  • CA Prop 65 (CJ for Wire & Cable): Yes
  • MII Order #39 (China RoHS): Yes

Flame Test

  • UL Flame Test: UL1685 FT4 Loading
  • CSA Flame Test: FT4
  • IEEE Flame Test: 1202

Suitability
Sunlight Resistance: Yes

Plenum/Non-Plenum
Plenum (Y/N): No

Electrical Characteristics (Overall)
Nom. Inductance:
Inductance (μH/ft) : .282

Nom. Mutual Capacitance:
Capacitance (pF/ft) : 8.5

Nominal Velocity of Propagation:
VP (%) : 78

Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft) : 16.0

Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 3.900 Ohm/1000 ft

Nom. Attenuation:

Freq. (MHz) Attenuation (dB/100 ft.)
0.200 0.270
4.000 0.670
16.000 1.370

Max. Attenuation:

Freq. (MHz) Attenuation (dB/100 ft.)
0.200 1.100
4.000 2.650
16.000 5.400

Max. Operating Voltage - UL:

Voltage
300 V RMS (NEC Type CMG)
600 V RMS (UL AWM Style 20201)
300V RMS (NEC Type PLTC)

Max. Recommended Current:

  • Description - Per Conductor
  • Current - 2.3 Amps

Other Electrical Characteristic 1: Capacitance Unbalance @ 1 kHz: Less than 1000 pF/km
Other Electrical Characteristic 2: Input Impedance/Unfitted Impedance 3 - 20 MHZ, 150 +-15 Ohms

Notes: Siemens Sinec L2 Cable. For CPE jacketed version order Part No. YR45047. For LS0H (FRNC) jacketed version, order Part No. YR44731.

Put Ups and Colors:

Item # Putup Ship Weight Color Notes Item Desc
3079A 0071000 1.000 FT 56.000 LB VIOLET C 1 PR #22 FRFPE FRPE SH PVC
3079A 0072000 2,000 FT 112.000 LB VIOLET c 1 PR #22 FRFPE FRPE SH PVC
3079A 0073600 3.600 FT 201.600 LB VIOLET c 1 PR #22 FRFPE FRPE SH PVC
3079A 0075000 5,000 FT 285.000 LB VIOLET 1 PR #22 FRFPE FRPE SH PVC
3079A 0601000 1,000 FT 56.000 LB CHROME c 1 PR #22 FRFPE FRPE SH PVC
3079A 0602000 2.000 FT 112.000 LB CHROME C 1 PR #22 FRFPE FRPE SH PVC
3079A 0603600 3.600 FT 201.600 LB CHROME C 1 PR #22 FRFPE FRPE SH PVC

YJ57083

Profibus DP Application

DESCRIPTION
22 AWG solid bare copper conductors, FHDPE insulation, overall Beldfoil® shielded plus tinned copper braid, overall PVC jacket.
PHYSICAL CHARACTERISTICS:
CONDUCTOR:
Number of Conductors 2
Nam. Conductor Stranding 1/0.65 mm
Nominal Conductor Gauge 22AWG
Conductor Material BC - Bare Copper
INSULATION:
Insulation Material FHDPE - Foam High Density Polyethylene
Nom. Insulation Diameter 2.5 mm
0\TRALL CABLING:  
Overall Cablmg Lay: 70 mm
Color Code Chart 1 Red
2 Green
OVERALL SHIELD:
Overall Shield Type & Material Beldfoil® Al-Mylar Tape + Tinned Copper Braid
OUTER JACKET:
Outer Jacket Material
PVC - Polyvinyl Chloride
Nom. Outer Jacket Wall Thickness 1.0 mm
OVERALL NOMINAL DIAMETER:
Overall Nominal Diameter 7.8 mm
MECHANICAL CHARACTERISTICS:
Temperature Rating
- 20℃ To + 70℃
Min. bending radius 15 x Cable Diameter
APPLICABLE SPECIFICATION AGENCY COMPLIANCE:
APPLICABLE STANDARDS:
EU RoHS Compliant (Y/N)
Y
EU RoHS Compliance Date June 2007
FLAME TEST:
Flame Test IEC 60332-1
PLENUM/NON-PLENUM:
Plenum (Y/N) N
ELECTRICAL CHARACTERISTICS:
Norn. Conductor DC Resistance @ 20°C 16 Q/kft
Nom. Capacitance Conductor to Conductor 8.5pF/ft
Nom. Impedance (3MHz - 20MHz) 150+/-15 olim
Nom. Velocity of Propagation 78%
Max. Attenuation @ 0.2 MHz l.lOdB/lOOmtr
Max. Attenuation @ 4 MHz 2.65 dB/lOOmtr
Max. Attenuation @ 16 MHz 5.40 dR/lOOmtr
Max. Operating Voltage 300 V

PUT-UPS AND COLORS:

Item Description Put-lp (M) Ship Weight (kg) Jacket Color
YJ57083 007500M 1 PR #22 FRFPE FRPE SH PVC 500 34 Violet
YJ57083 0071000M 1 PR #22 FRFPE FRPE SH PVC 1000 67 Violet
YJ57083 0071500M 1 PR #22 FRFPE FRPE SH PVC 1500 100 Violet

© 2016 M.E.M Industries . All rights reserved | Promoted by